Specifications | |
---|---|
Size | 3.3” H × 2.0” W × 1.1” D (85 mm H × 50 mm W × 28 mm D) |
Weight | 2.7 oz. (76 g) |
Temperature | H2S: -40°C to +50°C/ -40°F to +122°F CO: -40°C to +50°C/ -40°F to +122°F O2: -35°C to +50°C/ -58°F to +122°F |
Humidity | 5% to 95% non-condensing relative humidity |
Alarms | Visual, Vibrating and Audible (minimum 95 db) |
Tests | Full function self-test on activation and every 20 hours; continuous automatic battery and sensor tests |
Ratings | IP 67/ Complies with EMC directives 89/336/EEC |
Certifications | UL 913 and CSA-22.2 No 157 Class 1 Division 1&2 Groups A, B, C and D; ATEX: II 1 G Ex ia IIC T4; IECEX: Ex ia IIC T4 |
Warranty | 2 years from activation, 1 year shelf life |
Measuring Range | H2S: 0-100 (Low alarm limit: 10 ppm; High alarm limit: 15 ppm) CO: 0-300 ppm (Low alarm limit: 35 ppm; High alarm limit: 200 ppm) O2: 0-30% (volume) (Low alarm limit: 19.5%; High alarm limit: 23.5%) |
[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]
Features
Bump Check Reminder: All Single Gas Clip models come standard with the bump check reminder feature. When activated, if the detector has not been bump tested within the designated interval, the instrument will emit both a flash and show “buP” across the screen alerting the user, peer, or supervisor that the gas bump test is due. In addition to the flash, the TEST Icon will continually display in the upper left hand corner. This alert increases user accountability and allows for easier policy enforcement. Note the flash feature can be disabled within the IR Link software, if desired.
Programmable unique 6 digit ID: Considering the rugged environment these instruments are often exposed to and used in, identification via serial number, sticker, or marker can be unreliable. With the unique ID feature, units can be identified with a simple push of a button. Available using both limited alpha and full numeric characters, each unit can be assigned a unique ID utilizing, for example an employee ID number, last 4 digits of SSN, or a job code. Unique ID’s will also appear on event log reports and bump test logs. ID’s will be displayed on the detector screen in segments of 3 digits at a time (first 3 digits, then last 3 digits).
Adjustable alarm set points: To adapt with changing health and safety gas exposure regulations for workers in industrial environments, the Single Gas Clip alarm set points can be easily adjusted via the IR Link software or through the SGC Dock. Detectors can also be special ordered with custom alarm set points. Please contact your Gas Clip Technologies representative for more information.[/vc_column_text][/vc_column][/vc_row]